Table: Parameters range and default values.

ParameterName MinValue MaxValue DefaultValue
UpperZoneTimeConstant 0.01 40 10
LowerZoneTimeConstant 40 730 100
GwPercValue 0.01 2 0.8
LZThreshold 0 30 10
b_Xinanjiang 0.01 5 0.5
PowerPrefFlow 0.5 8 4
SnowMeltCoef 2.5 6.5 4
CalChanMan1 0.5 2 1
GwLoss 0 1.0 0
CalChanMan2 *SR 0.5 5 1
CalChanMan3 *MCT 0.5 5 1
LakeMultiplier *L 0.5 2 1
ReservoirFloodStorage *R 0.5 0.99 0.75
ReservoirFloodOutflowFactor *R 0.1 0.5 0.3
QSplitMult *SR 0 20 2
TransSub *TL 0 0.15 0

*L = this parameter is required when lakes are included in the modelling domain

*R = this parameter is required when reservoirs are included in the modelling domain

*SR = this parameter is required when using the split routing module

*MCT = this parameter is required when using diffusive routing (MCT)

*TL = this parameter is required when the transmission loss module is active

A detailed description of OS LISFLOOD standard and optional modules is available from the Model Documentation

The reservoir modelling routine was updated with OS LISFLOOD v5: the updated methodology is described in this page. Former versions of OS LISFLOOD code required the following parameters for reservoir modelling: | ParameterName | MinValue | MaxValue | DefaultValue | | :—————————– | —————–: | —————–: | —————–: | | adjust_Normal_Flood | 0.01 | 0.99 | 0.8 | | ReservoirRnormqMult | 0.25 | 2 | 1 |